Not known Factual Statements About ECLORplus Volume Corrector
Not known Factual Statements About ECLORplus Volume Corrector
Blog Article
Elcor Plus Gas Volume Converter Remember that all typical Dwyer flowmeters are calibrated for standard atmospheric pressure and temperature while in the bore.
Up to 6x electronic pressure transducer EDT96, or digital temperature transducer EDT101 with extended measuring ranges
The data of momentary values of pressure and temperature of gas is gained from precise measurement by pressure and temperature sensor in addition. At the battery feeding the cycle of measurement is programmable on the choice of one-thirty sec, at network version the momentary analogue values are scanned following 1 2nd.
대명아이티는 지금 서 있는 곳에서 만족하지 않고, 능동적이고 진취적인 경영시스템과 인재육성을 통하여 경쟁우위를 극대화하고 있습니다.
Throughout MSG production it's important to regulate flow in the course of the neutralization course of action. Regrettably, classic magnetic flowmeters come across precision troubles on account of coating on electrodes from liquids like crystal, slurry, and high-viscosity fluids.
Standing archive contains development and end of error, facts and time (five hundred information). Saved facts in archives is often evaluated by means of SW on PC following reading contents of archives
ELCOR-94 includes the circuits, which enable the interaction with surroundings. These circuits protected the galvanic separations of intrinsically Safe and sound circuits of ELCOR-ninety four within the setting. Appropriate communication might be carried out by two ways:
In the calculated values of absolute pressure and temperature and from rated worth of the compressibility diploma of gas it is actually calculated from running volume the standardised volume at referential problems.
angle on the way of liquid flow. The velocity on the signal traveling involving the transducers raises or decreases With all the path of transmission as well as velocity on the liquid becoming calculated. A time-differential relationship proportional to your flow may be received by transmitting the sign alternately in both directions. A limitation of your time-of-vacation meters is that the liquids staying measured needs to be comparatively freed from entrained gas or solids to minimize signal scattering and absorption.
a) by transfer by way of infrared gentle this transfer is realised in the clear window about the front side of ELCOR-94 by enclosing the communication head;
The flow amount below is basically determined by the pressure distinction between the two ends, the space involving them, and the realm from the conduit.
The unit incorporates an integral details logger which has a large 16MB memory, letting it to store calculated facts at hourly intervals for in excess of ten years.
The real key to some seamless finish that doesn’t peek via foundation boils down to the product you are utilizing. You’ll probably require a eco-friendly, a red, along with a peach to complete your kit, but the remainder of the process is fairly foolproof.
Module identification number Module designation Serial range of the module Amount of the slot during which the module is installed or maybe the identification of The interior communication bus to which the module (transducer) is related... Website page 99: System Configuration Menu High Pressure Flow Meter